Electrochemical Application of β-Al2O3 Membranes for Oxygen Reference Electrode in Melts

2001 ◽  
Vol 73 (6) ◽  
pp. 757-757
Author(s):  
V. Malyshev ◽  
V. Shapoval
TAPPI Journal ◽  
2010 ◽  
Vol 9 (7) ◽  
pp. 35-41
Author(s):  
OUTI A. HYÖKYVIRTA ◽  
TOM E. GUSTAFSSON

This investigation evaluated the applicability of a molybdenum sulfide reference electrode (MSRE) as an internal reference electrode for use in alkaline sulfide solutions over a range of pulp digester liquors at 170°C. The electrode remained stable during the exposure period of two weeks. The experimentally determined half cell potential of the MSRE is E = -0.91 VSHE. The surface of the MSRE was examined by scanning electron microscope (SEM) and electron spectroscopy for chemical analysis (ESCA) to verify the chemical composition of the thin surface film. Based on ESCA studies, the surface film contained molybdenum disulfide and sodium disulfide. During storage of the specimens, sulfide was partly oxidized to sodium sulfite in air. Next to the metallic molybdenum, a mixed molybdenum disulfide and molybdenum hydroxide layer was detected.


2020 ◽  
Vol 16 (3) ◽  
pp. 341-348
Author(s):  
Surinya Traipop ◽  
Suchada Chuanuwatanakul ◽  
Orawon Chailapakul ◽  
Eakkasit Punrat

Background: Recently, Derris scandens, a Thai herbal medicine with anti-inflammatory activity, is widely used as beverage and supplementary food. When the traditional medicine is a choice for health therapy, the simple and reliable equipment is required to control the suitable consuming amount of the active component. Objective: To develop the electrochemical sensor for genistein determination in Derris scandens with high sensitivity and rapid operation. Methods: An in-house screen-printed electrochemical sensor consisting of a three-electrode system was developed for genistein determination. A silver/silver chloride (Ag/AgCl) reference electrode, a carbon counter electrode and a carbon working electrode were prepared on a 0.3-mm-thick plastic substrate by the screen-printing technique using conductive ink. The dimensions of each sensor were 2.5×1.0 cm. Only 50 µL of sample solution was required on this device for the determination of genistein concentration by rapid response square wave voltammetry. Results: The oxidation peak of genistein appeared with good response in acidic media at a peak potential of 0.6 V. Moreover, the signal was enhanced by modifying the conductive carbon ink with cobalt( II) phthalocyanine. Under the optimized conditions, the linear range was found to be 2.5-150 µM and the detection limit was 1.5 µM. Moreover, the small volume extraction was successfully developed without any further pre-concentration. This proposed method was applied to determine genistein in Derris scandens with satisfying results. Conclusion: The proposed method is promising as an alternative method for genistein determination with facile and fast analysis.


Sensors ◽  
2020 ◽  
Vol 21 (1) ◽  
pp. 42
Author(s):  
Shimrith Paul Shylendra ◽  
Wade Lonsdale ◽  
Magdalena Wajrak ◽  
Mohammad Nur-E-Alam ◽  
Kamal Alameh

In this work, a solid-state potentiometric pH sensor is designed by incorporating a thin film of Radio Frequency Magnetron Sputtered (RFMS) Titanium Nitride (TiN) working electrode and a commercial Ag|AgCl|KCl double junction reference electrode. The sensor shows a linear pH slope of −59.1 mV/pH, R2 = 0.9997, a hysteresis as low as 1.2 mV, and drift below 3.9 mV/h. In addition, the redox interference performance of TiN electrodes is compared with that of Iridium Oxide (IrO2) counterparts. Experimental results show −32 mV potential shift (E0 value) in 1 mM ascorbic acid (reducing agent) for TiN electrodes, and this is significantly lower than the −114 mV potential shift of IrO2 electrodes with sub-Nernstian sensitivity. These results are most encouraging and pave the way towards the development of miniaturized, cost-effective, and robust pH sensors for difficult matrices, such as wine and fresh orange juice.


2008 ◽  
pp. 2046 ◽  
Author(s):  
Ruitao Lv ◽  
Lin Zou ◽  
Xuchun Gui ◽  
Feiyu Kang ◽  
Yanqiu Zhu ◽  
...  

1997 ◽  
Vol 20 (1) ◽  
pp. 37-42 ◽  
Author(s):  
K. Mabuchi ◽  
T. Chinzei ◽  
Y. Abe ◽  
K. Imanishi ◽  
T. Isoyama ◽  
...  

An electrochemical sensor system to allow real-time measurement and feedback of catecholamine concentrations was developed for use in the control of artificial hearts. Electrochemical analyses were carried out using a carbon fiber working electrode, an Ag-AgCI reference electrode, and a potentiostat. The operating parameters of the pneumatically-driven artificial heart system were altered in accordance with the algorithm for changes in the catecholamine concentration. The minimum detectable concentrations of both adrenaline and noradrenaline in a mock circulatory system using a phosphate-buffered solution were approximately 1-2 ng/ml (10-8 mol/L). An artificial heart control system utilizing this set-up performed satisfactorily without delay, although sensor sensitivity decreased when placed in goat plasma instead of a phosphate-buffered solution, due to the adsorption of various substances such as plasma proteins onto the electrodes. This study demonstrated the future feasibility of a feedback control system for artificial hearts using catecholamine concentrations.


Author(s):  
Matt D. Schalles ◽  
Dorian S. Houser ◽  
James J. Finneran ◽  
Peter Tyack ◽  
Barbara Shinn-Cunningham ◽  
...  

AbstractAuditory neuroscience in dolphins has largely focused on auditory brainstem responses; however, such measures reveal little about the cognitive processes dolphins employ during echolocation and acoustic communication. The few previous studies of mid- and long-latency auditory-evoked potentials (AEPs) in dolphins report different latencies, polarities, and magnitudes. These inconsistencies may be due to any number of differences in methodology, but these studies do not make it clear which methodological differences may account for the disparities. The present study evaluates how electrode placement and pre-processing methods affect mid- and long-latency AEPs in (Tursiops truncatus). AEPs were measured when reference electrodes were placed on the skin surface over the forehead, the external auditory meatus, or the dorsal surface anterior to the dorsal fin. Data were pre-processed with or without a digital 50-Hz low-pass filter, and the use of independent component analysis to isolate signal components related to neural processes from other signals. Results suggest that a meatus reference electrode provides the highest quality AEP signals for analyses in sensor space, whereas a dorsal reference yielded nominal improvements in component space. These results provide guidance for measuring cortical AEPs in dolphins, supporting future studies of their cognitive auditory processing.


Sign in / Sign up

Export Citation Format

Share Document